> > Skip to main content

Cold-resistant rf-shielding-box: IP Rating, Certifications, Lab Test Results | KeXinMaterials

Cold-resistant rf-shielding-box from KeXinMaterials source factory. OEM/ODM, wholesale, factory-direct pricing. 9 WL series sizes WL1204-WL5020, IP67/MIL-STD-810H certified, MOQ 50, 12h quote, 30-day delivery to 47 countries.

Cold-resistant rf-shielding-box Certifications: Why Buyers Care

Buyers who care about Cold-resistant rf-shielding-box certifications usually do so for a reason: their end customer requires it, or their insurance demands it, or their industry standard mandates it. We have shipped to all three.

The WL Series: 9 Standard Sizes for Cold-resistant rf-shielding-box

For your reference, here are the WL series models we typically use for Cold-resistant rf-shielding-box applications. Outer dimensions (OD) are measured to the outside of the case; inner dimensions (ID) reflect the usable cavity after subtracting wall thickness. All in millimeters; imperial dimensions in our catalog PDF.

ModelOuter (mm)Inner (mm)Weight (g)MaterialSize Class
WL1204 120×90×40 mm 115×78×32 mm 100 g PP Pistol Case
WL3812 380×320×120 mm 365×280×110 mm 1100 g PP+GF Rifle Case
WL8040 800×500×400 mm 770×470×370 mm 7800 g PP+GF Weapons & Ammo Pack

The most common model for "Cold-resistant rf-shielding-box" buyers is the WL1204 (120×90×40 mm OD, 100 g empty weight, PP body).

Temperature and Chemical Resistance of Cold-resistant rf-shielding-box

Cold-resistant rf-shielding-box shells are rated -40°C to +80°C per MIL-STD-810H Method 501.7 (high) and 502.7 (low). Chemically resistant to petroleum, mineral oil, dilute acids, alcohols, and most industrial solvents. Not resistant to concentrated sulfuric acid, aromatic, or chlorinated solvents.

The shell is rated IP67 + MIL-STD-810H ingress protection and validated to MIL-STD-810H Method 516.8 (26 drops at 2.0m). Temperature range is -50 ~ +90 °C. The automatic pressure-equalization valve keeps the seal intact during air transport and at altitude. Latch is a double-throw design rated for 5,000 open/close cycles. All units are 100% inspected for wall thickness uniformity, latch engagement, and foam adhesion before shipping.

Cold-resistant rf-shielding-box Foam Layouts: 200+ Reference Designs

We maintain 200+ foam-cut reference designs for Cold-resistant rf-shielding-box, covering camera bodies, drone kits, broadcast gear, military equipment, medical devices, and industrial tools. Send us your equipment list, we will match to the closest reference or draft a new layout free within 24 hours.

Cold-resistant rf-shielding-box Selection: Per-Profile Recommendations

For Cold-resistant rf-shielding-box: filmmakers should prioritize WL2808-WL5020 with custom foam. Drone operators: WL2005-WL2808 with battery cavities. Broadcast: WL3812-WL5020 with monitor + cable management. Military: WL3812-WL5020 with PP+GF and IP67. Medical: WL1504-WL2808 with anti-microbial foam.

For alternatives: soft padded bags (¥50–200, $7–30) are cheaper but offer no real protection and last 6 months. Aluminum hard cases ($80–300) are heavier, prone to denting, and 2–4× the price. Carbon fiber cases ($300+) are overkill for 95% of B2B use cases. Our PP/PC engineering cases hit the sweet spot: 90% of the protection of aluminum at 30% of the weight and 50% of the cost, with 10-year typical service life.

Cold-resistant rf-shielding-box After-Sales Support

After Cold-resistant rf-shielding-box ships: (1) We send QC photos before shipment. (2) Lot certificate with serial numbers. (3) 90-day defect replacement. (4) Foam re-cut service for equipment changes. (5) 5-year case body warranty. (6) Tooling stored 3 years for easy reorder.

Why Choose KeXinMaterials

Every certificate we publish is dated and serialized. We do not stock certificates — we issue them per batch.

Key Specifications

Ingress Protection
IP67 + MIL-STD-810H
Drop Test (MIL-STD-810H)
2.0m / 26 cycles
Temperature Range
-50 ~ +90 °C
Latch Type
Double-Throw Latch
Pressure Valve
Automatic Pressure Equalization
Certifications
ISO 9001:2015, MIL-STD-810H, IP67, IP68, ROHS

Why Source Directly from KeXinMaterials

Established 2014. 13,000 sqm factory in Fusha Industrial Park, Zhongshan, Guangdong. 12 production lines, 60+ injection molding machines, 100+ employees, 20+ patents. Monthly capacity 80,000 units. Annual export revenue 8M+ USD to 47 countries.

Direct from the OEM. Unlike trading companies or sourcing agents who add 15–40% markup and disappear after delivery, KeXinMaterials handles everything in-house: mold development, injection molding, foam CNC cutting, QC testing, export documentation. Our 2024 buyer survey showed 87% repeat-order rate and 0.3% defect rate across 47 countries.

Bulk Pricing Reference (FOB Shenzhen)

QuantityUnit PriceDiscountLead TimeSample
50-99 pcsUSD 12.35—20 daysFree (pay shipping)
100-199 pcsUSD 10.925% off25 daysFree (pay shipping)
200-499 pcsUSD 9.5010% off30 daysFree (pay shipping)
500-999 pcsUSD 8.5515% off30 daysFree (pay shipping)
1000+ pcsUSD 7.6020% off35-45 daysFree (pay shipping)

Reference price for WL1204 (120×90×40 mm). Custom sizes, colors, foam add 5–30%. Quote valid 30 days.

Quick Reference Infographic

Cold-resistant rf-shielding-box: Lab Test Certificate Reference

[ Infographic — generation in progress ]

Visual summary of the key specifications. Print-friendly for buyer reference.

Product Video: Cold-resistant rf-shielding-box

📹 Video — Coming Soon
Cold-resistant rf-shielding-box lab test footage: water submersion, drop test, temperature chamber
📧 Request Video

📹 60-second factory + product walkthrough. Cold-resistant rf-shielding-box lab test footage: water submersion, drop test, temperature chamber

Frequently Asked Questions

What is the fire rating?

UL94 V-2 standard (self-extinguishing within 30 seconds, no flaming drips). Higher UL94 V-0 rating available for select materials. We do not use materials with toxic flame retardants (Deca-BDE, HBCD) per ROHS.

What about chemical resistance?

Resistant to: petroleum products, mineral oil, dilute acids and alkalis, alcohols, and most industrial solvents. Not resistant to: concentrated sulfuric acid, aromatic solvents (benzene, toluene), and prolonged exposure to chlorinated solvents.

Does the case float in water?

Standard PP case: density 0.91 g/cm³, so yes, all our cases float. Foam-filled case with typical payload (5-30kg equipment): overall density may exceed 1.0, may not float. Specify float requirement and we adjust foam density.

What about EMI/RFI shielding?

Standard cases: no EMI/RFI shielding. Optional: conductive coating (nickel or copper) on interior surface for EMI shielding per MIL-STD-285. Adds $5-15 per unit depending on size. Used for sensitive electronic equipment.

What is the RoHS compliance for Cold-resistant rf-shielding-box?

ROHS 3 (EU 2015/863): compliant for all 10 restricted substances (Pb, Hg, Cd, Cr6+, PBB, PBDE, DEHP, BBP, DBP, DIBP). Third-party test report issued per batch, available as PDF on request.

Related Resources

Get a 12-Hour Quote for Cold-resistant rf-shielding-box

Free 5-day prototyping. ISO 9001 factory-direct. Ships to 47 countries.