> > Skip to content

Anti-static genetic-analyzer-case: IP Rating, Certifications, Lab Test Results | KeXinMaterials

Anti-static genetic-analyzer-case from KeXinMaterials source factory. OEM/ODM, wholesale, factory-direct pricing. 9 WL series sizes WL1204-WL5020, IP67/MIL-STD-810H certified, MOQ 30, 12h quote, 35-day delivery to 47 countries.

What Anti-static genetic-analyzer-case Actually Delivers: Numbers

What does Anti-static genetic-analyzer-case actually deliver? 1.2m concrete drop, 30 minutes at 1m underwater, -40 to +80°C, 5,000 latch cycles. We can show you the test videos and the SGS certificates.

Model Comparison: Which WL Series for Anti-static genetic-analyzer-case?

For Anti-static genetic-analyzer-case, the WL series splits into Small (WL1204-1504), Medium (WL1905-2808), and Large (WL3812-5020). Within each tier, 2-3 models vary in width and depth. We help you choose during the 12h quote consultation, but the table below is the reference.

ModelOuter (mm)Inner (mm)Weight (g)MaterialSize Class
WL2305 230×180×45 mm 225×150×40 mm 240 g PP+PC First Aid Kit
WL3812 380×320×120 mm 365×280×110 mm 1100 g PP+PC Vaccine Carrier
WL6030-O 600×450×300 mm 575×420×280 mm 4200 g PP+PC+VIP Organ Transport

The most common model for "Anti-static genetic-analyzer-case" buyers is the WL2305 (230×180×45 mm OD, 240 g empty weight, PP+PC body).

Anti-static genetic-analyzer-case Material Specs: PP, PP+GF, Foam Density

Shell material for Anti-static genetic-analyzer-case is selected per use case: standard PP for general purpose, PP+GF for heavy-duty (10% glass fiber improves impact strength by 35%). Foam is 25 kg/m³ closed-cell PE, 0.5mm CNC cut tolerance. Anti-static ESD foam (10^6-10^11 Ω) available for electronics.

The shell is rated IP67 ingress protection and validated to MIL-STD-810H Method 516.8 (26 drops at 1.5m). Temperature range is -80 ~ +50 (depending on PCM/VIP configuration) °C. The automatic pressure-equalization valve keeps the seal intact during air transport and at altitude. Latch is a double-throw design rated for 5,000 open/close cycles. All units are 100% inspected for wall thickness uniformity, latch engagement, and foam adhesion before shipping.

Anti-static genetic-analyzer-case Sample Layouts (2024-2026)

Here are 3 real Anti-static genetic-analyzer-case foam layouts from 2024-2026: (A) Sony A7 IV + 24-70mm + 70-200mm + 3 filters + 2 batteries — fits WL2808. (B) DJI Mavic 3 + RC + 4 batteries + charger — fits WL2005. (C) RED Komodo + 2 lenses + monitor + cables — fits WL5020. We share these at the 12h quote stage.

How to Choose Anti-static genetic-analyzer-case: Decision Framework

For Anti-static genetic-analyzer-case, the decision comes down to: equipment dimensions (always measure with 5-10mm foam clearance), IP rating (IP65 indoor, IP67 outdoor, IP68 water), and certification (FCC for USA, CE for EU, MIL-STD for military). Beyond that, it is foam layout and quantity discount.

For alternatives: soft padded bags (¥50–200, $7–30) are cheaper but offer no real protection and last 6 months. Aluminum hard cases ($80–300) are heavier, prone to denting, and 2–4× the price. Carbon fiber cases ($300+) are overkill for 95% of B2B use cases. Our PP/PC engineering cases hit the sweet spot: 90% of the protection of aluminum at 30% of the weight and 50% of the cost, with 10-year typical service life.

Anti-static genetic-analyzer-case: 5-Step Order Process

Ordering Anti-static genetic-analyzer-case is 5 steps: inquiry (12h response), quote (with recommendation), PO + 30% deposit, production (35 days + QC photos), balance payment + shipment. Repeat orders are 15-20 days. Custom OEM/ODM adds 25-30 days for mold.

Why Choose KeXinMaterials

Our quality management is ISO 9001:2015 certified. Our factory has been audited by SGS, TUV, and Bureau Veritas. Audit reports available on request.

Key Specifications

Ingress Protection
IP67
Drop Test (MIL-STD-810H)
1.5m / 26 cycles
Temperature Range
-80 ~ +50 (depending on PCM/VIP configuration) °C
Latch Type
Double-Throw Latch
Pressure Valve
Automatic Pressure Equalization
Certifications
ISO 9001:2015, ISO 13485 (Medical Devices), WHO PQS pre-qualified, FDA 21 CFR Part 820, CE MDR 2017/745

Why Source Directly from KeXinMaterials

Established 2014. 13,000 sqm factory in Fusha Industrial Park, Zhongshan, Guangdong. 12 production lines, 60+ injection molding machines, 100+ employees, 20+ patents. Monthly capacity 80,000 units. Annual export revenue 8M+ USD to 47 countries.

Direct from the OEM. Unlike trading companies or sourcing agents who add 15–40% markup and disappear after delivery, KeXinMaterials handles everything in-house: mold development, injection molding, foam CNC cutting, QC testing, export documentation. Our 2024 buyer survey showed 87% repeat-order rate and 0.3% defect rate across 47 countries.

Bulk Pricing Reference (FOB Shenzhen)

QuantityUnit PriceDiscountLead TimeSample
50-99 pcsUSD 15.08—20 daysFree (pay shipping)
100-199 pcsUSD 13.345% off25 daysFree (pay shipping)
200-499 pcsUSD 11.6010% off30 daysFree (pay shipping)
500-999 pcsUSD 10.4415% off30 daysFree (pay shipping)
1000+ pcsUSD 9.2820% off35-45 daysFree (pay shipping)

Reference price for WL2305 (230×180×45 mm). Custom sizes, colors, foam add 5–30%. Quote valid 30 days.

Quick Reference Infographic

Anti-static genetic-analyzer-case: Lab Test Certificate Reference

[ Infographic — generation in progress ]

Visual summary of the key specifications. Print-friendly for buyer reference.

Product Video: Anti-static genetic-analyzer-case

📹 Video — Coming Soon
Anti-static genetic-analyzer-case lab test footage: water submersion, drop test, temperature chamber
📧 Request Video

📹 60-second factory + product walkthrough. Anti-static genetic-analyzer-case lab test footage: water submersion, drop test, temperature chamber

Frequently Asked Questions

What about EMI/RFI shielding?

Standard cases: no EMI/RFI shielding. Optional: conductive coating (nickel or copper) on interior surface for EMI shielding per MIL-STD-285. Adds $5-15 per unit depending on size. Used for sensitive electronic equipment.

What is the RoHS compliance for Anti-static genetic-analyzer-case?

ROHS 3 (EU 2015/863): compliant for all 10 restricted substances (Pb, Hg, Cd, Cr6+, PBB, PBDE, DEHP, BBP, DBP, DIBP). Third-party test report issued per batch, available as PDF on request.

What is the warranty on Anti-static genetic-analyzer-case?

5-year warranty on case body and latch (covers manufacturing defects, not normal wear). 1-year warranty on foam set (covers material degradation, not mechanical damage). Warranty does not cover misuse, modifications, or cosmetic damage.

What is the recyclability?

PP and PP+GF cases are 100% recyclable. We have a take-back program for end-of-life cases from large customers (1,000+ units / year): we collect, shred, and reuse the regrind in non-critical components.

Is your Anti-static genetic-analyzer-case rating real or marketing?

All IP ratings are third-party tested by SGS, TUV, or Intertek at our lab in Zhongshan, Guangdong. We test every new mold design to IP67 and select models to IP68. Test certificates are dated and serialized.

Related Resources

Get a 12-Hour Quote for Anti-static genetic-analyzer-case

Free 5-day prototyping. ISO 9001 factory-direct. Ships to 47 countries.